General technical information Elstein BSI Units.

Used Elstein Infrared radiators : Type Elstein HTS   –   122 x 122 mm
Power Elstein Infrared radiators : 250 Watt up to 1.000 Watt
Operating temperature : 450°C up to 860°C
Wavelength range :  2 – 10 µm
Dimensions Infrared surface : 125 x 125 mm up to 1.500 x 1.000 mm
Specific surface rating : 16 up to 64 kW/m2
Available Integrated thermocouple : Type “K”  –  NiCr-Ni

Wilmod Infraredsystems

Elstein BSI Unit  –  Standard

Elstein BSIThe Elstein BSI Unit Standard is completely made of stainless steel.
This type of units are structured in such a way that it simply can be laid in a frame, it can be used upwards and downwards.
The internal electrical connections are prepared with power strips instead of cable, for a long life and a reliable operation.
The customer can configure his own unit with a maximum of 4 heating zones for power control or with pilot heaters for temperature control.
The connection cables for this type are not included.

For more information see PDF below :
Wilmod Elstein Infraredsystems – BSI
Wilmod Elstein Infraredsystems – HTS

Configure your own Elstein BSI unit :

Configure Elstein BSI Unit StandardX

  • Type
  • Dimensions
  • Heating zones
  • T-Heaters
  • Summary

Heater type

Select your heater type

HTS 250
HTS 400
HTS 600
HTS 800
HTS 1000

Dimensions

Click on a cell to determine your grid

Backside view

Heating Zones

Click to position active zone elements on the grid

Backside view

Select a zone to configure

zone 1 (default)
zone 2
zone 3
zone 4

T-Heaters

Click to add / remove T-Heaters

Backside view

Type:
Layout:

Dimensions:

Elements:

Backside view
Maximum Power Consumption:
Company
Name
Address
PC en Place
Country
Telephone
E-mail
Message

 
Copy anti-spam code:captcha

Type: Dimensions: Elements: Power:

Configure

Wilmod Infraredsystems

Elstein BSI Unit  –  Complete

Elstein BSIThe Elstein BSI Unit Complete is completely made of stainless steel.
This type of units are structured in such a way that it simply can be laid in a frame, it can be used upwards and downwards.
The internal electrical connections are prepared with power strips instead of cable, for a long life and a reliable operation.
The customer can configure his own unit with a maximum of 4 heating zones for power control or with pilot heaters for temperature control.
The connection cables with metal hose are included and connected.

For more information see PDF below :
Wilmod Elstein Infraredsystems – BSI
Wilmod Elstein Infraredsystems – HTS

Configure your own Elstein BSI unit :

Configure Elstein BSI Unit CompleteX

  • Type
  • Dimensions
  • Heating zones
  • T-Heaters
  • Cable
  • Summary

Heater type

Select your heater type

HTS 250
HTS 400
HTS 600
HTS 800
HTS 1000

Dimensions

Click on a cell to determine your grid

Backside view

Heating Zones

Click to position active zone elements on the grid

Backside view

Select a zone to configure

zone 1 (default)
zone 2
zone 3
zone 4

T-Heaters

Click to add / remove T-Heaters

Backside view

Cables

Select required cable length

1 meter
2 meter
3 meter
4 meter
5 meter

Type:
Layout:

Dimensions:

Elements:

Backside view
Maximum Power Consumption:
Cable:
Company
Name
Address
PC en Place
Country
Telephone
E-mail
Message

 
Copy anti-spam code:captcha

Type: Dimensions: Elements: Power:

Configure

Wilmod Infraredsystems

Elstein BSI Unit  –  Custom Made

Elstein BSIThe BSI Unit Custom Made is completely made of stainless steel.
You can choose for the standard Elstein frame mounting or a custom-specific mounting with bolts or threaded rods.
The internal electrical connection is depending from the configuration with power strips for a long life.
You choose a Custom Made unit when you need more than 4 heating zones or other electrical connection or mounting.
For more information see the PDF below or send us an e-mail.

For more information see PDF below :
Wilmod Elstein Infraredsystems – HTS